How to create existing sections
Example section
Your sections must:
- be drawn to scale (usually 1:100 or 1:50 at A3 or A4 size)
- show a scale bar
- have a unique drawing reference number
You should include:
- an off-site datum point as a point of reference for levels
- floor to ceiling heights within the building
- eaves, foundations and retaining structures if they might encroach onto adjoining land
- voids if there are any within the building